This paper presents a novel application of active single-drop microextraction (SDME) for the determination of mixtures of four gaseous diisocyanates: 2,4- and 2,6-toluene diisocyanate (TDI), hexamethylene diisocyanate (HDI) and methylene diphenyl diisocyanate (MDI). The optimised simultaneous extraction, preconcentration and derivatization method utilizes a 2.3-mu L Milli-Q water drop containing dibutylamine (DBA) as a derivatization reagent and phenylisocyanate (PHI) as an injection standard. A type III screening design, combined with Box-Behnken surface modelling and Simplex optimisation was applied to optimise the method. Several SDME approaches - standard SDME, automatic organic solvent film (OSF) and use of a supported-drop (SD) device - were compared with solid-phase microextraction (SPME) in terms of sensitivity and robustness under varied conditions. Of these SDME alternatives, SD proved to be the most suitable for diisocyanate sampling. The detection limits using SDME followed by UPLC-MS-MS analysis were 0.9 and 0.8 mu g m(-3) for 2,4- and 2,6-TDI, respectively, 1.0 mu g m(-3) for HDI and 0.2 mu g m(-3) for MDI. (C) 2008 Elsevier B.V. All rights reserved.

Active single-drop microextraction for the determination of gaseous diisocyanates

CRESCENZI, Carlo
2008-01-01

Abstract

This paper presents a novel application of active single-drop microextraction (SDME) for the determination of mixtures of four gaseous diisocyanates: 2,4- and 2,6-toluene diisocyanate (TDI), hexamethylene diisocyanate (HDI) and methylene diphenyl diisocyanate (MDI). The optimised simultaneous extraction, preconcentration and derivatization method utilizes a 2.3-mu L Milli-Q water drop containing dibutylamine (DBA) as a derivatization reagent and phenylisocyanate (PHI) as an injection standard. A type III screening design, combined with Box-Behnken surface modelling and Simplex optimisation was applied to optimise the method. Several SDME approaches - standard SDME, automatic organic solvent film (OSF) and use of a supported-drop (SD) device - were compared with solid-phase microextraction (SPME) in terms of sensitivity and robustness under varied conditions. Of these SDME alternatives, SD proved to be the most suitable for diisocyanate sampling. The detection limits using SDME followed by UPLC-MS-MS analysis were 0.9 and 0.8 mu g m(-3) for 2,4- and 2,6-TDI, respectively, 1.0 mu g m(-3) for HDI and 0.2 mu g m(-3) for MDI. (C) 2008 Elsevier B.V. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/1846519
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 24
social impact