This paper discusses issues related to the design method of transformers for switching converters based on the use of the geometric constant K gfe of magnetic cores. It is shown that some inherent assumptions in the application of the method can be misleading if the effects of specific combinations of geometric measures and thermal properties of the magnetic cores are not properly considered. An example regarding the design of the transformer for a low-power multi-output isolated dc-dc forward converter is presented and discussed.

Geometric-constants-based design of transformers for isolated switching converters

DE NARDO, ANTONIETTA;DI CAPUA, Giulia;FEMIA, Nicola;PETRONE, GIOVANNI;SPAGNUOLO, Giovanni
2010-01-01

Abstract

This paper discusses issues related to the design method of transformers for switching converters based on the use of the geometric constant K gfe of magnetic cores. It is shown that some inherent assumptions in the application of the method can be misleading if the effects of specific combinations of geometric measures and thermal properties of the magnetic cores are not properly considered. An example regarding the design of the transformer for a low-power multi-output isolated dc-dc forward converter is presented and discussed.
2010
9781424463909
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/3009661
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact