In this paper the performances of the Automatic Alignment sensing and control system in the Virgo gravitational wave detector, during the second scientific run from July 7th 2009 to January 8th 2010, are described. The accuracy of the angular control loops fulfills the original Virgo requirements, reaching the accuracy of a few nano-radians for the most critical angular degrees of freedom, and the control noise is below the Virgo design sensitivity in the whole detection band.

Automatic Alignment system during the second science run of the Virgo interferometer

ACERNESE, Fausto;BARONE, Fabrizio;ROMANO, Rocco;
2011-01-01

Abstract

In this paper the performances of the Automatic Alignment sensing and control system in the Virgo gravitational wave detector, during the second scientific run from July 7th 2009 to January 8th 2010, are described. The accuracy of the angular control loops fulfills the original Virgo requirements, reaching the accuracy of a few nano-radians for the most critical angular degrees of freedom, and the control noise is below the Virgo design sensitivity in the whole detection band.
2011
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/3017330
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact