LC-MS-based shotgun proteomics relies both on the power of the separation techniques and the sensitivity of detection methods. As a viable alternative to classical approaches in this field, we developed a fully automated, comprehensive 2D LC system, in which RPLC × RPLC was coupled to MS detection, for the first time, and applied for the analysis of tryptic digests obtained from α-casein and dephosphorylated α-casein. The use of a significantly different pH in the two dimensions allowed us to attain high peak capacity, despite the employment of novel identical stationary phases. Furthermore, such a combination addresses compatibility issues, thus allowing straightforward interfacing in online 2D LC configuration, as well as direct linkage to a mass spectrometer. A theoretical peak capacity of ca. 8500 was calculated for the setup, employing four serially coupled C18 columns in the first dimension (600 × 2.1 mm, 2.7 μm d.p.), operated under basic conditions, and 3 cm length of the same stationary phase (30 × 4.6 mm, 2.7 μm d.p. column), under acidic conditions, for fast second dimension analysis.

Online Comprehensive RPLC × RPLC with Mass Spectrometry Detection for the Analysis of Proteome Samples

Eduardo Sommella;CAMPIGLIA, Pietro;
2011-01-01

Abstract

LC-MS-based shotgun proteomics relies both on the power of the separation techniques and the sensitivity of detection methods. As a viable alternative to classical approaches in this field, we developed a fully automated, comprehensive 2D LC system, in which RPLC × RPLC was coupled to MS detection, for the first time, and applied for the analysis of tryptic digests obtained from α-casein and dephosphorylated α-casein. The use of a significantly different pH in the two dimensions allowed us to attain high peak capacity, despite the employment of novel identical stationary phases. Furthermore, such a combination addresses compatibility issues, thus allowing straightforward interfacing in online 2D LC configuration, as well as direct linkage to a mass spectrometer. A theoretical peak capacity of ca. 8500 was calculated for the setup, employing four serially coupled C18 columns in the first dimension (600 × 2.1 mm, 2.7 μm d.p.), operated under basic conditions, and 3 cm length of the same stationary phase (30 × 4.6 mm, 2.7 μm d.p. column), under acidic conditions, for fast second dimension analysis.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/3040119
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 53
social impact