A molecularly imprinted polymer was prepared using (E)-resveratrol as template and was evaluated for multicomponent multiclass analysis of polyphenolic compounds in complex matrices such as natural and alcoholic beverages. Chromatographic evaluation of the polymer exhibited high selectivity for (E)-resveratrol and its structural analogues, quercetin, and other flavonoids. An analytical procedure based on molecularly imprinted solid phase extraction (MISPE) and high-performance liquid chromatography coupled to UV detector was developed and validated for determination of (E)-resveratrol and quercetin in wine and fruit juice samples. The specific binding capacity of the MIP was estimated as 80 μg g(-1) polymer by the cartridge test. MISPE sample pretreatment allows an excellent sample cleanup, enormously decreasing the number of coextracted potentially interfering compounds. Under the described conditions, by extracting 2 mL samples a clean extract is obtained and (E)-resveratrol and quercetin could be easily identified at concentration levels of, respectively, 1.5 and 7.0 μg L(-1).

Development and Validation of a Method for the Determination of (E)-Resveratrol and Related Phenolic Compounds in Beverages Using Molecularly Imprinted Solid Phase Extraction

EUTERPIO, MARIA ANNA;Imma Pagano;PICCINELLI, ANNA LISA;RASTRELLI, Luca;CRESCENZI, Carlo
2013-01-01

Abstract

A molecularly imprinted polymer was prepared using (E)-resveratrol as template and was evaluated for multicomponent multiclass analysis of polyphenolic compounds in complex matrices such as natural and alcoholic beverages. Chromatographic evaluation of the polymer exhibited high selectivity for (E)-resveratrol and its structural analogues, quercetin, and other flavonoids. An analytical procedure based on molecularly imprinted solid phase extraction (MISPE) and high-performance liquid chromatography coupled to UV detector was developed and validated for determination of (E)-resveratrol and quercetin in wine and fruit juice samples. The specific binding capacity of the MIP was estimated as 80 μg g(-1) polymer by the cartridge test. MISPE sample pretreatment allows an excellent sample cleanup, enormously decreasing the number of coextracted potentially interfering compounds. Under the described conditions, by extracting 2 mL samples a clean extract is obtained and (E)-resveratrol and quercetin could be easily identified at concentration levels of, respectively, 1.5 and 7.0 μg L(-1).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/3922771
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 27
social impact