OBJECTIVES:The aim of this study was to evaluate the effect of sodium enoxaparin treatment on patients with noise-induced hearing loss. METHODS: Sixty patients with noise-induced hearing loss were included and randomly divided into two numerically equal groups. Group A underwent therapy with sodium enoxaparin for 10 days, followed by an additional 10 days of treatment after 10 days of no treatment. Group B received placebo as a control. Before treatment, at the end of treatment, and 2 months after the end of treatment, all patients underwent evaluation by laboratory tests, pure tone audiometry, transient evoked otoacoustic emissions (TEOAEs) testing, distortion product otoacoustic emissions (DPOAEs) testing, and auditory brain stem response testing. RESULTS: In contrast to group B, at the end of the treatment in group A pure tone audiometry showed a significant (p < 0.05) improvement of the audiometric thresholds at 0.5, 1, 2, 4, and 8 kHz. Depending on the air and bone conduction thresholds, TEOAEs and DPOAEs, which had previously been absent, were evoked at the frequencies examined. These improvements were confirmed at last follow-up. We found no significant differences in auditory brain stem responses or laboratory results. CONCLUSIONS: These preliminary data encourage further studies to collect additional evidence on the effect of sodium enoxaparin in preventing the development of noise-induced hearing loss.

Audiometric Characteristics in Patients With Noise-Induced Hearing Loss After Sodium Enoxaparin Treatment

SALZANO, Francesco Antonio;
2012-01-01

Abstract

OBJECTIVES:The aim of this study was to evaluate the effect of sodium enoxaparin treatment on patients with noise-induced hearing loss. METHODS: Sixty patients with noise-induced hearing loss were included and randomly divided into two numerically equal groups. Group A underwent therapy with sodium enoxaparin for 10 days, followed by an additional 10 days of treatment after 10 days of no treatment. Group B received placebo as a control. Before treatment, at the end of treatment, and 2 months after the end of treatment, all patients underwent evaluation by laboratory tests, pure tone audiometry, transient evoked otoacoustic emissions (TEOAEs) testing, distortion product otoacoustic emissions (DPOAEs) testing, and auditory brain stem response testing. RESULTS: In contrast to group B, at the end of the treatment in group A pure tone audiometry showed a significant (p < 0.05) improvement of the audiometric thresholds at 0.5, 1, 2, 4, and 8 kHz. Depending on the air and bone conduction thresholds, TEOAEs and DPOAEs, which had previously been absent, were evoked at the frequencies examined. These improvements were confirmed at last follow-up. We found no significant differences in auditory brain stem responses or laboratory results. CONCLUSIONS: These preliminary data encourage further studies to collect additional evidence on the effect of sodium enoxaparin in preventing the development of noise-induced hearing loss.
2012
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4652178
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact