Home-made micro-solid-phase extraction (SPE) cartridges using different adsorbent materials were tested for the desorption electrospray ionization-high-resolution mass spectrometry (DESI-HRMS) determination of explosives like 2,4,6-trinitrotoluene, cyclotrimethylene-trinitramine, cyclotetramethylene-tetranitramine, pentaerythritol tetranitrate, and trinitrophenylmethylnitramine in soil samples. Quantitation limits in the low nanogram per kilogram range proved the reliability of the method for the detection of explosives at ultra-trace levels. The reduced sample preparation allowed for low costs and high-throughput analyses. Finally, the superior extraction capability of the method was proved by obtaining DESI-HRMS responses at least five times higher than those achieved by performing DESI-HRMS analyses of solid-liquid extracts spotted onto commercial polytetrafluoroethylene slides.
Micro-solid-phase extraction coupled to desorption electrospray ionization-high-resolution mass spectrometry for the analysis of explosives in soil
CRESCENZI, Carlo;
2015-01-01
Abstract
Home-made micro-solid-phase extraction (SPE) cartridges using different adsorbent materials were tested for the desorption electrospray ionization-high-resolution mass spectrometry (DESI-HRMS) determination of explosives like 2,4,6-trinitrotoluene, cyclotrimethylene-trinitramine, cyclotetramethylene-tetranitramine, pentaerythritol tetranitrate, and trinitrophenylmethylnitramine in soil samples. Quantitation limits in the low nanogram per kilogram range proved the reliability of the method for the detection of explosives at ultra-trace levels. The reduced sample preparation allowed for low costs and high-throughput analyses. Finally, the superior extraction capability of the method was proved by obtaining DESI-HRMS responses at least five times higher than those achieved by performing DESI-HRMS analyses of solid-liquid extracts spotted onto commercial polytetrafluoroethylene slides.File | Dimensione | Formato | |
---|---|---|---|
48 Micro-solid-phase extraction coupled to desorption electrospray ionization–high-resolution mass spectrometry for the analysis of explosives in soil.pdf
non disponibili
Tipologia:
Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
918.75 kB
Formato
Adobe PDF
|
918.75 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.