This work reports the results of an experimental programme aimed at investigating the in-plane behaviour of clay-brick masonry walls externally strengthened by carbon fiber reinforced polymer (CFRP) strips. Particularly, four different geometrical layouts were considered for the CFRP strips, though keeping unchanged the quantity of composites employed in each wall. Firstly, a preliminary experimental work was carried out on samples of the constitutive materials for quantifying their key mechanical properties and evaluating the bond behaviour of FRP strips on the masonry substrates. Then, eleven cyclic shear-compression tests were performed to observe the response of strengthened walls and the influence of the strengthening layouts under investigation. The proposed experimental report is intended as a contribution to the current state of knowledge about the behaviour of FRP-strengthened masonry walls: it is available to assess the accuracy and possibly improve the predictive capacity of design-oriented capacity models. Finally, the comparison of the reported experimental results with the predictions obtained by applying the analytical relationships proposed by a recently issued guideline for FRP strengthening of masonry structures is proposed.

Cyclic shear-compression tests on masonry walls strengthened with alternative configurations of CFRP strips

MARTINELLI, Enzo
;
PERRI, FRANCESCO;SGUAZZO, CARMEN;FAELLA, Ciro
2016-01-01

Abstract

This work reports the results of an experimental programme aimed at investigating the in-plane behaviour of clay-brick masonry walls externally strengthened by carbon fiber reinforced polymer (CFRP) strips. Particularly, four different geometrical layouts were considered for the CFRP strips, though keeping unchanged the quantity of composites employed in each wall. Firstly, a preliminary experimental work was carried out on samples of the constitutive materials for quantifying their key mechanical properties and evaluating the bond behaviour of FRP strips on the masonry substrates. Then, eleven cyclic shear-compression tests were performed to observe the response of strengthened walls and the influence of the strengthening layouts under investigation. The proposed experimental report is intended as a contribution to the current state of knowledge about the behaviour of FRP-strengthened masonry walls: it is available to assess the accuracy and possibly improve the predictive capacity of design-oriented capacity models. Finally, the comparison of the reported experimental results with the predictions obtained by applying the analytical relationships proposed by a recently issued guideline for FRP strengthening of masonry structures is proposed.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4675224
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 18
social impact