Two different tannery sewage sludges (sludge 1 and sludge 2) have been characterized by thermal analysis coupled with mass spectrometry of evolved gases (TG-DSC-MS), inductively coupled plasma-atomic emission spectrometry (ICP-AES), Gas chromatography - mass spectrometry (GC-MS), Purge and trap GC-MS. Four main temperature ranges of weight loss are individuated in air flow TG-DSC-MS experiments on sludge 1. The first, below 200°C, coupled to an endothermic signal, is related to water release. Between 200 and 350°C, an exothermic signal accompanies the loss of sulphate as evolved SO2, and organic substances, aromatics and saturated cyclic compounds. In the latter range, development of CO2 was also observed, that becomes prevalent in the range 350-600°C. From 600 to 700°C carbon dioxide coming from carbonate decomposition was observed. On sludge 2 three main temperature ranges of weight loss are present, below 150°C, between 150 and 350°C and from 350 to 600°C, attributed, respectively, to water, sulphate, CO2 plus aromatic and carbonylic compounds releases. A larger amount of Cr and Al was found by ICP-AES on sludge 2. The differences between the samples evidence the influence of the different composition of the parent wastewater and of the depuration process. The influence of additives on combustion profiles has been also evaluated. Catalyst addition to the sludge results to reduce the emission of cyclic and aromatic substances, to lower temperature and to increase the oxidation rate of the organic fraction combustion.

A thermogravimetric study on tannery sewage sludges

CIAMBELLI, Paolo;SANNINO, Diana;VAIANO, VINCENZO;CALVANESE, GIUDITTA
2013-01-01

Abstract

Two different tannery sewage sludges (sludge 1 and sludge 2) have been characterized by thermal analysis coupled with mass spectrometry of evolved gases (TG-DSC-MS), inductively coupled plasma-atomic emission spectrometry (ICP-AES), Gas chromatography - mass spectrometry (GC-MS), Purge and trap GC-MS. Four main temperature ranges of weight loss are individuated in air flow TG-DSC-MS experiments on sludge 1. The first, below 200°C, coupled to an endothermic signal, is related to water release. Between 200 and 350°C, an exothermic signal accompanies the loss of sulphate as evolved SO2, and organic substances, aromatics and saturated cyclic compounds. In the latter range, development of CO2 was also observed, that becomes prevalent in the range 350-600°C. From 600 to 700°C carbon dioxide coming from carbonate decomposition was observed. On sludge 2 three main temperature ranges of weight loss are present, below 150°C, between 150 and 350°C and from 350 to 600°C, attributed, respectively, to water, sulphate, CO2 plus aromatic and carbonylic compounds releases. A larger amount of Cr and Al was found by ICP-AES on sludge 2. The differences between the samples evidence the influence of the different composition of the parent wastewater and of the depuration process. The influence of additives on combustion profiles has been also evaluated. Catalyst addition to the sludge results to reduce the emission of cyclic and aromatic substances, to lower temperature and to increase the oxidation rate of the organic fraction combustion.
2013
9786056402302
9786056402302
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4676369
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact