The main purpose of the present work was the completion and the thermo-fluid dynamic characterization of a Rotary Permanent Magnet Magnetic Refrigerator operating at room temperature. The experimental device consists of 8 static regenerators packed with gadolinium (Gd) spheres inside a rotating two-pole permanent magnet with a magnetic field of 1.25 T and an air gap of 43 mm. A rotary valve mechanically coupled to the field generator imparts the direction of heat transfer fluid through the regenerators. A parametric study of the temperature span, cooling power and coefficient of performance (COP) was carried out over a range of different hot reservoir temperatures, volumetric flow rates, cycle frequency and cooling powers. The experimental investigation has been identified by 468 tests on 33 measured quantities, obtaining the thermo-fluid dynamic characterization of the complete machine in stationary operation. Finally, with the aim of optimising the performance of the prototype, a new regenerator has been developed. The new design allows reducing the dead volume and improves the fluid distribution around the magnetic refrigerant. [edited by Author]

Caratterizzazione termo-fluidodinamica ed ottimizzazione delle prestazioni di un prototipo di refrigeratore magnetico a magneti permanenti rotanti operante a temperatura ambiente , 2016 Apr 11., Anno Accademico 2014 - 2015.

Caratterizzazione termo-fluidodinamica ed ottimizzazione delle prestazioni di un prototipo di refrigeratore magnetico a magneti permanenti rotanti operante a temperatura ambiente

-
2016

Abstract

The main purpose of the present work was the completion and the thermo-fluid dynamic characterization of a Rotary Permanent Magnet Magnetic Refrigerator operating at room temperature. The experimental device consists of 8 static regenerators packed with gadolinium (Gd) spheres inside a rotating two-pole permanent magnet with a magnetic field of 1.25 T and an air gap of 43 mm. A rotary valve mechanically coupled to the field generator imparts the direction of heat transfer fluid through the regenerators. A parametric study of the temperature span, cooling power and coefficient of performance (COP) was carried out over a range of different hot reservoir temperatures, volumetric flow rates, cycle frequency and cooling powers. The experimental investigation has been identified by 468 tests on 33 measured quantities, obtaining the thermo-fluid dynamic characterization of the complete machine in stationary operation. Finally, with the aim of optimising the performance of the prototype, a new regenerator has been developed. The new design allows reducing the dead volume and improves the fluid distribution around the magnetic refrigerant. [edited by Author]
11-apr-2016
Ingegneria meccanica
Sergi, Vincenzo
Aprea, Ciro
File in questo prodotto:
File Dimensione Formato  
157625453377006655858112937961820210877

accesso aperto

Tipologia: Altro materiale allegato
Dimensione 219.65 kB
Formato Adobe PDF
219.65 kB Adobe PDF Visualizza/Apri
164307931652734909882253510498701589174

accesso aperto

Tipologia: Altro materiale allegato
Dimensione 3.58 MB
Formato Adobe PDF
3.58 MB Adobe PDF Visualizza/Apri
40619495326911771589842223846274470926

accesso aperto

Tipologia: Altro materiale allegato
Dimensione 128.68 kB
Formato Adobe PDF
128.68 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4923726
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact