The main purpose of the present work was the completion and the thermo-fluid dynamic characterization of a Rotary Permanent Magnet Magnetic Refrigerator operating at room temperature. The experimental device consists of 8 static regenerators packed with gadolinium (Gd) spheres inside a rotating two-pole permanent magnet with a magnetic field of 1.25 T and an air gap of 43 mm. A rotary valve mechanically coupled to the field generator imparts the direction of heat transfer fluid through the regenerators. A parametric study of the temperature span, cooling power and coefficient of performance (COP) was carried out over a range of different hot reservoir temperatures, volumetric flow rates, cycle frequency and cooling powers. The experimental investigation has been identified by 468 tests on 33 measured quantities, obtaining the thermo-fluid dynamic characterization of the complete machine in stationary operation. Finally, with the aim of optimising the performance of the prototype, a new regenerator has been developed. The new design allows reducing the dead volume and improves the fluid distribution around the magnetic refrigerant. [edited by Author]
Caratterizzazione termo-fluidodinamica ed ottimizzazione delle prestazioni di un prototipo di refrigeratore magnetico a magneti permanenti rotanti operante a temperatura ambiente , 2016 Apr 11., Anno Accademico 2014 - 2015.
Caratterizzazione termo-fluidodinamica ed ottimizzazione delle prestazioni di un prototipo di refrigeratore magnetico a magneti permanenti rotanti operante a temperatura ambiente
-
2016
Abstract
The main purpose of the present work was the completion and the thermo-fluid dynamic characterization of a Rotary Permanent Magnet Magnetic Refrigerator operating at room temperature. The experimental device consists of 8 static regenerators packed with gadolinium (Gd) spheres inside a rotating two-pole permanent magnet with a magnetic field of 1.25 T and an air gap of 43 mm. A rotary valve mechanically coupled to the field generator imparts the direction of heat transfer fluid through the regenerators. A parametric study of the temperature span, cooling power and coefficient of performance (COP) was carried out over a range of different hot reservoir temperatures, volumetric flow rates, cycle frequency and cooling powers. The experimental investigation has been identified by 468 tests on 33 measured quantities, obtaining the thermo-fluid dynamic characterization of the complete machine in stationary operation. Finally, with the aim of optimising the performance of the prototype, a new regenerator has been developed. The new design allows reducing the dead volume and improves the fluid distribution around the magnetic refrigerant. [edited by Author]| File | Dimensione | Formato | |
|---|---|---|---|
|
157625453377006655858112937961820210877
accesso aperto
Tipologia:
Altro materiale allegato
Dimensione
219.65 kB
Formato
Adobe PDF
|
219.65 kB | Adobe PDF | Visualizza/Apri |
|
164307931652734909882253510498701589174
accesso aperto
Tipologia:
Altro materiale allegato
Dimensione
3.58 MB
Formato
Adobe PDF
|
3.58 MB | Adobe PDF | Visualizza/Apri |
|
40619495326911771589842223846274470926
accesso aperto
Tipologia:
Altro materiale allegato
Dimensione
128.68 kB
Formato
Adobe PDF
|
128.68 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.