This paper presents the most significant results obtained within a broad-ranging experimental program aiming to evaluate both the effectiveness and the robustness of a Base Isolation (BIS) and a Tuned Mass Damper (TMD) combined control strategy (BIS & TMD). Following a brief description of the experimental model set-up and the adopted cinematic scaling technique, this paper describes the identification procedures carried out to characterize the system’s model. The dynamic response of a small-scale model to recorded earthquake excitations, which has been scaled by using the Buckingham pi-theorem, are later presented and discussed. Finally, the effectiveness and robustness of the combined control strategy is evaluated by comparing the model’s dynamic response. In particular, reduction in relative displacements and absolute accelerations due to the application of different mass damping systems is investigated. Il lavoro indaga, mediante una campagna sperimentale, l’efficacia e la robustezza della strategia combinata di controllo BI&TMD, ottenuta dalla combinazione di Isolamento alla Base (BIS) e Smorzamento di Massa (TMD). Dopo una breve descrizione della strumentazione hardware impiegata e dei modelli in piccola scala realizzati per la sperimentazione, si presentano e discutono i principali risultati ottenuti. In particolare, dei modelli realizzati sulla base di leggi di similitudine cinematica, sono stati inizialmente identificati i parametri dinamici principali, periodi e smorzamenti. Successivamente, sono state descritte ed analizzate sia la risposta nel dominio delle frequenze dei modelli fissi, isolati ed isolati con smorzamento di massa, che la risposta nel tempo degli stessi ad eventi sismici registrati. Infine, è stata indagata l’efficacia e la robustezza della strategia di controllo combinata BI&TMD mediante l’analisi comparata della risposta sismica dei modelli sperimentali con TMD attivo o bloccato. [a cura dell'Autore]

Sperimentazione su tavola vibrante della strategia innovativa di protezione sismica bis&tmd mediante modelli in scala , 2011 Jul 25., Anno Accademico 2009 - 2010.

Sperimentazione su tavola vibrante della strategia innovativa di protezione sismica bis&tmd mediante modelli in scala

-
2011

Abstract

This paper presents the most significant results obtained within a broad-ranging experimental program aiming to evaluate both the effectiveness and the robustness of a Base Isolation (BIS) and a Tuned Mass Damper (TMD) combined control strategy (BIS & TMD). Following a brief description of the experimental model set-up and the adopted cinematic scaling technique, this paper describes the identification procedures carried out to characterize the system’s model. The dynamic response of a small-scale model to recorded earthquake excitations, which has been scaled by using the Buckingham pi-theorem, are later presented and discussed. Finally, the effectiveness and robustness of the combined control strategy is evaluated by comparing the model’s dynamic response. In particular, reduction in relative displacements and absolute accelerations due to the application of different mass damping systems is investigated. Il lavoro indaga, mediante una campagna sperimentale, l’efficacia e la robustezza della strategia combinata di controllo BI&TMD, ottenuta dalla combinazione di Isolamento alla Base (BIS) e Smorzamento di Massa (TMD). Dopo una breve descrizione della strumentazione hardware impiegata e dei modelli in piccola scala realizzati per la sperimentazione, si presentano e discutono i principali risultati ottenuti. In particolare, dei modelli realizzati sulla base di leggi di similitudine cinematica, sono stati inizialmente identificati i parametri dinamici principali, periodi e smorzamenti. Successivamente, sono state descritte ed analizzate sia la risposta nel dominio delle frequenze dei modelli fissi, isolati ed isolati con smorzamento di massa, che la risposta nel tempo degli stessi ad eventi sismici registrati. Infine, è stata indagata l’efficacia e la robustezza della strategia di controllo combinata BI&TMD mediante l’analisi comparata della risposta sismica dei modelli sperimentali con TMD attivo o bloccato. [a cura dell'Autore]
25-lug-2011
Ingegneria delle strutture e del recupero edilizio e urbano
Ingegneria sismica
Tavola vibrante
Faella, Ciro
Petti, Luigi
File in questo prodotto:
File Dimensione Formato  
146895923892496554638160388389046136523.pdf

accesso aperto

Tipologia: Altro materiale allegato
Dimensione 157.27 kB
Formato Adobe PDF
157.27 kB Adobe PDF Visualizza/Apri
158536185776361802539620980056915315988.pdf

accesso aperto

Tipologia: Altro materiale allegato
Dimensione 2.18 MB
Formato Adobe PDF
2.18 MB Adobe PDF Visualizza/Apri
69037637283850079847396792028031941792.pdf

accesso aperto

Tipologia: Altro materiale allegato
Dimensione 46.64 kB
Formato Adobe PDF
46.64 kB Adobe PDF Visualizza/Apri
91215902866465509753023878598402037150.pdf

accesso aperto

Tipologia: Altro materiale allegato
Dimensione 23.05 kB
Formato Adobe PDF
23.05 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4924629
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact