In this paper, an approach for placement of voltage regulators (VRs) in traditional distribution systems by considering a local controller model is presented. The main aims of this paper are controlling the voltage level in its permitted range and decreasing the costs imposed to the distribution system companies, such as costs that stem from power losses, VRs’ investment and maintenance. Genetic algorithm (GA) has been used as a tool to determine the number, location and rated power of VRs. Since in traditional distribution systems, tap position determination of VRs is achieved by local controllers, local controller model is established to determine tap operations. A 70-bus distribution system is considered to prove the value of the presented approach. Effectiveness of the proposed approach and ineffectiveness and infeasibility of conventional approaches are presented in numerical studies. The presented approach allowed to eliminate voltage violation in all load conditions and a reduction of power losses of about 6% for the maximum load level.

A novel strategy for optimal placement of locally controlled voltage regulators in traditional distribution systems

Siano, Pierluigi
2018-01-01

Abstract

In this paper, an approach for placement of voltage regulators (VRs) in traditional distribution systems by considering a local controller model is presented. The main aims of this paper are controlling the voltage level in its permitted range and decreasing the costs imposed to the distribution system companies, such as costs that stem from power losses, VRs’ investment and maintenance. Genetic algorithm (GA) has been used as a tool to determine the number, location and rated power of VRs. Since in traditional distribution systems, tap position determination of VRs is achieved by local controllers, local controller model is established to determine tap operations. A 70-bus distribution system is considered to prove the value of the presented approach. Effectiveness of the proposed approach and ineffectiveness and infeasibility of conventional approaches are presented in numerical studies. The presented approach allowed to eliminate voltage violation in all load conditions and a reduction of power losses of about 6% for the maximum load level.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4704360
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 22
social impact