The work hereinafter discussed concerns the evaluation of the seismic performances of a traditional Moment Resisting Frame and a Moment Resisting Frame equipped with friction dampers, called "FREEDAM". A multi-records IDA analysis has been performed and the results have been evaluated in terms of interstorey drift for each storey.
Comments on IDA analysis results for MRFs with and without FREEDAM connections
Streppone S.
2019
Abstract
The work hereinafter discussed concerns the evaluation of the seismic performances of a traditional Moment Resisting Frame and a Moment Resisting Frame equipped with friction dampers, called "FREEDAM". A multi-records IDA analysis has been performed and the results have been evaluated in terms of interstorey drift for each storey.File in questo prodotto:
Non ci sono file associati a questo prodotto.