Capacitive deionization (CDI), a promising ion removal technology, has shown encouraging results in the last decade. In this work a comprehensive characterization of a CDI prototype equipped with 3D graphite felt electrodes is shown. Initially, a study of different flow distributor designs, analyzed by Computational Flow Dynamic (CFD), determined the importance of elements such as small inlet cavities or perforated channels to achieve a uniform fluid flow distribution. Then, an evaluation under different operational parameters and modes (batch and single pass, SP) demonstrated the strong flexibility in terms of performance that the CDI system is able to offer. Thus, in general terms, SP experiments were able to produce larger quantities of water (14–47 L h−1 m−2) than batch experiments (2–24 L h−1 m−2) although obtaining lower salt concentration reductions (1–2 mM vs 6–10 mM, respectively). The CDI stack was tested for 350 galvanostatic cycles (700 h of operation) showing an exceptional robustness in performance. Energy consumption values below 200 Wh m−3 were obtained for SP experiments, whereas that value increased to 600 Wh m−3 for batch tests. Nevertheless, by implementing an energy recovery system these values could be reduced by an average of 40–50%.

Performance analysis of a capacitive deionization stack for brackish water desalination

Cartolano V.;Senatore V.;Naddeo V.;Anderson M. A.
2021-01-01

Abstract

Capacitive deionization (CDI), a promising ion removal technology, has shown encouraging results in the last decade. In this work a comprehensive characterization of a CDI prototype equipped with 3D graphite felt electrodes is shown. Initially, a study of different flow distributor designs, analyzed by Computational Flow Dynamic (CFD), determined the importance of elements such as small inlet cavities or perforated channels to achieve a uniform fluid flow distribution. Then, an evaluation under different operational parameters and modes (batch and single pass, SP) demonstrated the strong flexibility in terms of performance that the CDI system is able to offer. Thus, in general terms, SP experiments were able to produce larger quantities of water (14–47 L h−1 m−2) than batch experiments (2–24 L h−1 m−2) although obtaining lower salt concentration reductions (1–2 mM vs 6–10 mM, respectively). The CDI stack was tested for 350 galvanostatic cycles (700 h of operation) showing an exceptional robustness in performance. Energy consumption values below 200 Wh m−3 were obtained for SP experiments, whereas that value increased to 600 Wh m−3 for batch tests. Nevertheless, by implementing an energy recovery system these values could be reduced by an average of 40–50%.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4757985
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 24
social impact