The Planar Wide-Mesh Scanning (PWMS) methodology is based on Non-redundant scanning schemes allowing faster measurements than classical Nyquist-compliant acquisitions based on denser, regular, equally spaced Planar Near Field (PNF) sampling. The methodology has no accuracy loss and has been validated at different bands and with different antennas. The effectiveness of the PWMS technique has always been proven in error-free (or quasi-error-free) scenarios, assuming that possible errors introduced by the technique itself are independent on the typical sources of measurement uncertainty. In this paper, we investigate for the first time the sensibility of the method wrt one of this error source included in the 18-terms lists considered by the measurement community as an exhaustive list of the NF errors: X and Y probe positioning errors. Such errors are typically unknown and random and are associated to the mechanical vibrations and/or backlash of the system. The investigation has been done considering actual measurements of a multi-beam reflector antenna with approximately 35 dBi gain. The test was performed at 22-33 GHz introducing uniformly distributed random errors in the range [0-1] mm, corresponding to λ/10 at 30 GHz.

Sensitivity analysis of fast non-redundant NF sampling methodologies with probe positioning errors

D'Agostino F.;Ferrara F.;Gennarelli C.;Guerriero R.;
2020-01-01

Abstract

The Planar Wide-Mesh Scanning (PWMS) methodology is based on Non-redundant scanning schemes allowing faster measurements than classical Nyquist-compliant acquisitions based on denser, regular, equally spaced Planar Near Field (PNF) sampling. The methodology has no accuracy loss and has been validated at different bands and with different antennas. The effectiveness of the PWMS technique has always been proven in error-free (or quasi-error-free) scenarios, assuming that possible errors introduced by the technique itself are independent on the typical sources of measurement uncertainty. In this paper, we investigate for the first time the sensibility of the method wrt one of this error source included in the 18-terms lists considered by the measurement community as an exhaustive list of the NF errors: X and Y probe positioning errors. Such errors are typically unknown and random and are associated to the mechanical vibrations and/or backlash of the system. The investigation has been done considering actual measurements of a multi-beam reflector antenna with approximately 35 dBi gain. The test was performed at 22-33 GHz introducing uniformly distributed random errors in the range [0-1] mm, corresponding to λ/10 at 30 GHz.
2020
978-1-7281-9868-2
978-1-7362351-0-2
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4764108
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact