An ultrasensitive and selective voltammetric sensor with an ultratrace-level detection limit is introduced for ketoconazole (KTC) determination in real samples using a modified carbon paste electrode with a sheaf-like Ce-BTC MOF nanostructure and ionic liquid. The as-synthesized nanostructure was characterized by several techniques, including energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD), and field emission scanning electron microscopy (FE-SEM). The electrocatalytic performance of the developed electrode was observed by cyclic voltammetry (CV), differential pulse voltammetry (DPV), linear sweep voltammetry (LSV), and chronoamperometry. The limit of detection (LOD) of the developed sensor for KTC is 0.04 μM, and the response was found to be in the dynamic concentration range of 0.1–110.0 μM in a phosphate buffer solution. The proposed electrode exhibits acceptable electrocatalytic activity for KTC oxidation with a high sensitivity of 0.1342 μA·μM−1. The ability of the fabricated sensor to monitor KTC in real aqueous samples is demonstrated using standard addition data.

A New Electrochemical Sensor for the Detection of Ketoconazole Using Carbon Paste Electrode Modified with Sheaf-like Ce-BTC MOF Nanostructure and Ionic Liquid

Di Bartolomeo, Antonio
Writing – Review & Editing
2023-01-01

Abstract

An ultrasensitive and selective voltammetric sensor with an ultratrace-level detection limit is introduced for ketoconazole (KTC) determination in real samples using a modified carbon paste electrode with a sheaf-like Ce-BTC MOF nanostructure and ionic liquid. The as-synthesized nanostructure was characterized by several techniques, including energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD), and field emission scanning electron microscopy (FE-SEM). The electrocatalytic performance of the developed electrode was observed by cyclic voltammetry (CV), differential pulse voltammetry (DPV), linear sweep voltammetry (LSV), and chronoamperometry. The limit of detection (LOD) of the developed sensor for KTC is 0.04 μM, and the response was found to be in the dynamic concentration range of 0.1–110.0 μM in a phosphate buffer solution. The proposed electrode exhibits acceptable electrocatalytic activity for KTC oxidation with a high sensitivity of 0.1342 μA·μM−1. The ability of the fabricated sensor to monitor KTC in real aqueous samples is demonstrated using standard addition data.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4815031
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact