We theoretically study the behavior of the critical current of a thermally biased tunnel Josephson junction with a particular design, in which the electrodes of the junction are enclosed in two different superconducting loops pierced by independent magnetic fluxes. In this setup, the superconducting gaps can be modified independently through the magnetic fluxes threading the loops. We investigate the response of the device as a function of the magnetic fluxes, by changing the asymmetry parameter, i.e., the ratio between the zero-temperature superconducting gaps 8 = A10/A20 and the temperatures of the two rings. We show a magnetically controllable steplike response of the critical current, which emerges even in a symmetric junction, 8 = 1. Finally, we discuss the optimal working conditions and the high response of the critical current to small changes in the magnetic flux, reporting good performance of a magnetic flux-to-critical current transducer, with a high transfer function that depends on the operating point, the temperature gradient, and the quality of the junction.

Temperature-Biased Double-Loop Josephson Flux Transducer

C. Guarcello
;
R. Citro;A. Braggio
2022-01-01

Abstract

We theoretically study the behavior of the critical current of a thermally biased tunnel Josephson junction with a particular design, in which the electrodes of the junction are enclosed in two different superconducting loops pierced by independent magnetic fluxes. In this setup, the superconducting gaps can be modified independently through the magnetic fluxes threading the loops. We investigate the response of the device as a function of the magnetic fluxes, by changing the asymmetry parameter, i.e., the ratio between the zero-temperature superconducting gaps 8 = A10/A20 and the temperatures of the two rings. We show a magnetically controllable steplike response of the critical current, which emerges even in a symmetric junction, 8 = 1. Finally, we discuss the optimal working conditions and the high response of the critical current to small changes in the magnetic flux, reporting good performance of a magnetic flux-to-critical current transducer, with a high transfer function that depends on the operating point, the temperature gradient, and the quality of the junction.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4817616
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact