Introduction: Modern endodontics aims to decrease the bacterial load from the complex endodontic space. Over the years, improvements in the operative phases have led to a considerable increase in the success rate of endodontic treatments. The shaping phase has seen the development of new techniques supported by technological innovations that have led to higher treatment predictability. Endodontic instruments have experienced a series of changes that have led to modifications in their design, surface treatments, and heat treatments. The clinical use of rotating nickel-titanium instruments has become widespread and consolidated, a success due primarily to the alloy's mechanical characteristics, which are superior to steel ones, but also to innovations in instrument design. The advent of the Ni-Ti alloy has kept the concepts and requirements of shaping the same but has modified its implementation in endodontics. Aim: The following review followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) protocol. The research question focused on Ni-Ti endodontic instruments whose cyclic fatigue was evaluated by analyzing cyclic fatigue strength and the incidence of fracture. Results: At the end of the research, 10 systematic reviews and 1 randomized controlled trial were included in this comprehensive review. The most frequently analysed alloys were M-wire, conventional Ni-Ti, and CM-wire. In seven articles, instruments made of M-wire alloy were used; in eight articles, instruments made of conventional Ni-Ti; and in seven articles, instruments made of CM-wire alloy. Conclusions: The technological evolution of Ni-Ti alloys has led to the development of increasingly high-performance endodontic files that are resistant to cyclic fatigue during clinical practice and have greater resistance to sterilisation practices, making treatment easier and more predictable over time. In particular, heat-treated nickel-titanium root canal instruments present greater resistance to cyclic fatigue than untreated ones and those used with reciprocating kinematics concerning continuous rotation.

Cyclic Fatigue of Different Ni-Ti Endodontic Rotary File Alloys: A Comprehensive Review

Iandolo, Alfredo;Scorziello, Michela;Sangiovanni, Giuseppe;Pisano, Massimo
2024-01-01

Abstract

Introduction: Modern endodontics aims to decrease the bacterial load from the complex endodontic space. Over the years, improvements in the operative phases have led to a considerable increase in the success rate of endodontic treatments. The shaping phase has seen the development of new techniques supported by technological innovations that have led to higher treatment predictability. Endodontic instruments have experienced a series of changes that have led to modifications in their design, surface treatments, and heat treatments. The clinical use of rotating nickel-titanium instruments has become widespread and consolidated, a success due primarily to the alloy's mechanical characteristics, which are superior to steel ones, but also to innovations in instrument design. The advent of the Ni-Ti alloy has kept the concepts and requirements of shaping the same but has modified its implementation in endodontics. Aim: The following review followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) protocol. The research question focused on Ni-Ti endodontic instruments whose cyclic fatigue was evaluated by analyzing cyclic fatigue strength and the incidence of fracture. Results: At the end of the research, 10 systematic reviews and 1 randomized controlled trial were included in this comprehensive review. The most frequently analysed alloys were M-wire, conventional Ni-Ti, and CM-wire. In seven articles, instruments made of M-wire alloy were used; in eight articles, instruments made of conventional Ni-Ti; and in seven articles, instruments made of CM-wire alloy. Conclusions: The technological evolution of Ni-Ti alloys has led to the development of increasingly high-performance endodontic files that are resistant to cyclic fatigue during clinical practice and have greater resistance to sterilisation practices, making treatment easier and more predictable over time. In particular, heat-treated nickel-titanium root canal instruments present greater resistance to cyclic fatigue than untreated ones and those used with reciprocating kinematics concerning continuous rotation.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4867494
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact