Background and Objectives: To achieve success in endodontic treatment, it is essential to properly perform the steps of shaping, cleansing and obturation. Determining the working length of the canal is, therefore, a process that must be precise and accurate. Electronic apex locators are a useful tool for the clinician to best perform this step of endodontic treatment. Materials and Methods: The purpose of the following umbrella review is to evaluate, through data in the literature, the degree of accuracy of apex locators. Results: Seven systematic reviews were included in the following umbrella review. Five compare the accuracy of apex locators versus radiographic techniques, two compare different types of electronic apex locators, and two analyze the determination of working length in primary teeth. Conclusions: From the results obtained from the following umbrella review, albeit at low levels of evidence, the methods for determining working length using electronic apex locators and other methods, particularly using radiographic evaluation, are equally valid.

Evaluation of the Accuracy of Electronic Apex Locators in Modern Endodontics: An Umbrella Review

Pisano, Massimo;Sangiovanni, Giuseppe;Scorziello, Michela;Iandolo, Alfredo
2024-01-01

Abstract

Background and Objectives: To achieve success in endodontic treatment, it is essential to properly perform the steps of shaping, cleansing and obturation. Determining the working length of the canal is, therefore, a process that must be precise and accurate. Electronic apex locators are a useful tool for the clinician to best perform this step of endodontic treatment. Materials and Methods: The purpose of the following umbrella review is to evaluate, through data in the literature, the degree of accuracy of apex locators. Results: Seven systematic reviews were included in the following umbrella review. Five compare the accuracy of apex locators versus radiographic techniques, two compare different types of electronic apex locators, and two analyze the determination of working length in primary teeth. Conclusions: From the results obtained from the following umbrella review, albeit at low levels of evidence, the methods for determining working length using electronic apex locators and other methods, particularly using radiographic evaluation, are equally valid.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4888131
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact