High-efficiency alkali antimonide photocathodes degrade with little oxidation, making them hard to characterize and test outside their growth chamber. In this proceeding, we report on the design and performance of the PHOtocathode Epitaxy and Beam Experiments (PHOEBE) laboratory at Cornell University, where the growth, characterization, and testing of alkali photocathodes in vacuum has been successfully integrated. The growth of photocathodes is characterized in-situ by measuring the QE and by looking at the photocathode’s reflection high energy electron diffraction (RHEED) pattern. Once the desired photocathode is obtained, it is moved to a storage chamber to collect spectral response data, after which it is moved to the cryogenic emittancediagnostic beamline via a vacuum suitcase. A rapid cathode exchange system in the diagnostic beam can efficiently transfer alkali-antimonide photocathodes to beamline operation with little QE loss. Using this beamline, the mean transverse energy of the photocathode can be measured at various photoexcitation wavelengths in the visible spectrum and sample temperatures within 20 - 300 K.

PHOtocathode Epitaxy and Beam Experiments laboratory at Cornell: current status and future work

A. Galdi;
2024

Abstract

High-efficiency alkali antimonide photocathodes degrade with little oxidation, making them hard to characterize and test outside their growth chamber. In this proceeding, we report on the design and performance of the PHOtocathode Epitaxy and Beam Experiments (PHOEBE) laboratory at Cornell University, where the growth, characterization, and testing of alkali photocathodes in vacuum has been successfully integrated. The growth of photocathodes is characterized in-situ by measuring the QE and by looking at the photocathode’s reflection high energy electron diffraction (RHEED) pattern. Once the desired photocathode is obtained, it is moved to a storage chamber to collect spectral response data, after which it is moved to the cryogenic emittancediagnostic beamline via a vacuum suitcase. A rapid cathode exchange system in the diagnostic beam can efficiently transfer alkali-antimonide photocathodes to beamline operation with little QE loss. Using this beamline, the mean transverse energy of the photocathode can be measured at various photoexcitation wavelengths in the visible spectrum and sample temperatures within 20 - 300 K.
2024
978-3-95450-247-9
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4949107
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact