The Virgo gravitational wave detector is an interferometer (ITF) with 3 km arms located in Pisa, Italy. From July to October 2010, Virgo performed its third science run (VSR3) in coincidence with the LIGO detectors. Despite several techniques adopted to isolate the ITF from the environment, seismic noise remains an important issue for Virgo. Vibrations produced by the detector infrastructure (such as air conditioning units, water chillers/heaters, pumps) are found to affect Virgo’s sensitivity, with the main coupling mechanisms being through beam jitter and scattered light processes. The Advanced Virgo design seeks to reduce ITF couplings to environmental noise by having most vibrationsensitive components suspended and in vacuum, as well as muffle and relocate loud machines. During the months of June and July in 2010, a G¨uralp-3TD seismometer was stationed at various locations around the Virgo site hosting major infrastructure machines. Seismic data were examined using spectral and coherence analysis with seismic probes close to the detector. The primary aim of this study was to identify noisy machines which seismically affect the ITF environment and thus require mitigation attention. Analyzed machines are located at various distances from the experimental halls, ranging from 10 to 100 m. An attempt is made to measure the attenuation of emitted noise at the ITF and correlate it with the distance from the source and with seismic attenuation models in soil.

Characterization of the Virgo seismic environment

ACERNESE, Fausto;BARONE, Fabrizio;ROMANO, Rocco;
2012-01-01

Abstract

The Virgo gravitational wave detector is an interferometer (ITF) with 3 km arms located in Pisa, Italy. From July to October 2010, Virgo performed its third science run (VSR3) in coincidence with the LIGO detectors. Despite several techniques adopted to isolate the ITF from the environment, seismic noise remains an important issue for Virgo. Vibrations produced by the detector infrastructure (such as air conditioning units, water chillers/heaters, pumps) are found to affect Virgo’s sensitivity, with the main coupling mechanisms being through beam jitter and scattered light processes. The Advanced Virgo design seeks to reduce ITF couplings to environmental noise by having most vibrationsensitive components suspended and in vacuum, as well as muffle and relocate loud machines. During the months of June and July in 2010, a G¨uralp-3TD seismometer was stationed at various locations around the Virgo site hosting major infrastructure machines. Seismic data were examined using spectral and coherence analysis with seismic probes close to the detector. The primary aim of this study was to identify noisy machines which seismically affect the ITF environment and thus require mitigation attention. Analyzed machines are located at various distances from the experimental halls, ranging from 10 to 100 m. An attempt is made to measure the attenuation of emitted noise at the ITF and correlate it with the distance from the source and with seismic attenuation models in soil.
2012
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/3120034
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact