Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
UniSa - IRIS Institutional Research Information System
This paper presents a complete description of Virgo, the French-Italian gravitational wave detector. The detector, built at Cascina, near Pisa (Italy), is a very large Michelson interferometer, with 3 km-long arms. In this paper, following a presentation of the physics requirements, leading to the specifications for the construction of the detector, a detailed description of all its different elements is given.These include civil engineering infrastructures, a huge ultra-high vacuum (UHV) chamber (about 6000 cubic metres), all of the optical components, including high quality mirrors and their seismic isolating suspensions, all of the electronics required to control the interferometer and for signal detection. The expected performances of these different elements are given, leading to an overall sensitivity curve as a function of the incoming gravitational wave frequency. This description represents the detector as built and used in the first data-taking runs. Improvements in different parts have been and continue to be performed, leading to better sensitivities. These will be detailed in a forthcoming paper.
Virgo: a laser interferometer to detect gravitational waves
T. Accadia;ACERNESE, Fausto;M. Alshourbagy;P. Amico;F. Antonucci;S. Aoudia;N. Arnaud;C. Arnault;K. G. Arun;P. Astone;S. Avino;D. Babusci;G. Ballardin;BARONE, Fabrizio;G. Barrand;L. Barsotti;M. Barsuglia;A. Basti;Th S. Bauer;F. Beauville;M. Bebronne;M. Bejger;M. G. Beker;F. Bellachia;A. Belletoile;J. L. Beney;M. Bernardini;S. Bigotta;R. Bilhaut;S. Birindelli;M. Bitossi;M. A. Bizouard;M. Blom;C. Boccara;D. Boget;F. Bondu;L. Bonelli;R. Bonnand;V. Boschi;L. Bosi;T. Bouedo;B. Bouhou;A. Bozzi;L. Bracci;S. Braccini;C. Bradaschia;M. Branchesi;T. Briant;A. Brillet;V. Brisson;L. Brocco;T. Bulik;H. J. Bulten;D. Buskulic;C. Buy;G. Cagnoli;G. Calamai;E. Calloni;E. Campagna;B. Canuel;F. Carbognani;L. Carbone;F. Cavalier;R. Cavalieri;R. Cecchi;G. Cella;E. Cesarini;E. Chassande Mottin;S. Chatterji;R. Chiche;A. Chincarini;A. Chiummo;N. Christensen;A. C. Clapson;F. Cleva;E. Coccia;P. F. Cohadon;C. N. Colacino;J. Colas;A. Colla;M. Colombini;G. Conforto;A. Corsi;S. Cortese;F. Cottone;J. P. Coulon;E. Cuoco;S. D'Antonio;G. Daguin;A. Dari;V. Dattilo;P. Y. David;M. Davier;R. Day;G. Debreczeni;G. De Carolis;M. Dehamme;R. Del Fabbro;W. Del Pozzo;M. del Prete;L. Derome;R. De Rosa;R. DeSalvo;M. Dialinas;L. Di Fiore;A. Di Lieto;M. Di Paolo Emilio;A. Di Virgilio;A. Dietz;M. Doets;P. Dominici;A. Dominjon;M. Drago;C. Drezen;B. Dujardin;B. Dulach;C. Eder;A. Eleuteri;D. Enard;M. Evans;L. Fabbroni;V. Fafone;H. Fang;I. Ferrante;F. Fidecaro;I. Fiori;R. Flaminio;D. Forest;L. A. Forte;J. D. Fournier;L. Fournier;J. Franc;O. Francois;S. Frasca;F. Frasconi;A. Freise;A. Gaddi;M. Galimberti;L. Gammaitoni;P. Ganau;C. Garnier;F. Garufi;M. E. Gáspár;G. Gemme;E. Genin;A. Gennai;G. Gennaro;L. Giacobone;A. Giazotto;G. Giordano;L. Giordano;C. Girard;R. Gouaty;A. Grado;M. Granata;V. Granata;X. Grave;C. Greverie;H. Groenstege;G. M. Guidi;S. Hamdani;J. F. Hayau;S. Hebri;A. Heidmann;H. Heitmann;P. Hello;G. Hemming;E. Hennes;R. Hermel;P. Heusse;L. Holloway;D. Huet;M. Iannarelli;P. Jaranowski;D. Jehanno;L. Journet;S. Karkar;T. Ketel;H. Voet;J. Kovalik;I. Kowalska;S. Kreckelbergh;A. Krolak;J. C. Lacotte;B. Lagrange;P. La Penna;M. Laval;J. C. Le Marec;N. Leroy;N. Letendre;T. G. F. Li;B. Lieunard;N. Liguori;O. Lodygensky;B. Lopez;M. Lorenzini;V. Loriette;G. Losurdo;M. Loupias;J. M. Mackowski;T. Maiani;E. Majorana;C. Magazzù;I. Maksimovic;V. Malvezzi;N. Man;S. Mancini;B. Mansoux;M. Mantovani;F. Marchesoni;F. Marion;P. Marin;J. Marque;F. Martelli;A. Masserot;L. Massonnet;G. Matone;L. Matone;M. Mazzoni;F. Menzinger;C. Michel;L. Milano;Y. Minenkov;S. Mitra;M. Mohan;J. L. Montorio;R. Morand;F. Moreau;J. Moreau;N. Morgado;A. Morgia;S. Mosca;V. Moscatelli;B. Mours;P. Mugnier;F. A. Mul;L. Naticchioni;I. Neri;F. Nocera;E. Pacaud;G. Pagliaroli;A. Pai;L. Palladino;C. Palomba;F. Paoletti;R. Paoletti;A. Paoli;S. Pardi;G. Parguez;M. Parisi;A. Pasqualetti;R. Passaquieti;D. Passuello;M. Perciballi;B. Perniola;G. Persichetti;S. Petit;M. Pichot;F. Piergiovanni;M. Pietka;R. Pignard;L. Pinard;R. Poggiani;P. Popolizio;T. Pradier;M. Prato;G. A. Prodi;M. Punturo;P. Puppo;K. Qipiani;O. Rabaste;D. S. Rabeling;I. Rácz;F. Raffaelli;P. Rapagnani;S. Rapisarda;V. Re;A. Reboux;T. Regimbau;V. Reita;A. Remilleux;F. Ricci;I. Ricciardi;F. Richard;M. Ripepe;F. Robinet;A. Rocchi;L. Rolland;ROMANO, Rocco;D. Rosińska;P. Roudier;P. Ruggi;G. Russo;L. Salconi;V. Sannibale;B. Sassolas;D. Sentenac;S. Solimeno;R. Sottile;L. Sperandio;R. Stanga;R. Sturani;B. Swinkels;M. Tacca;R. Taddei;L. Taffarello;M. Tarallo;S. Tissot;A. Toncelli;M. Tonelli;O. Torre;E. Tournefier;F. Travasso;C. Tremola;E. Turri;G. Vajente;J. F. J. van den Brand;C. Van Den Broeck;S. van der Putten;M. Vasuth;M. Vavoulidis;G. Vedovato;D. Verkindt;F. Vetrano;O. Véziant;A. Viceré;J. Y. Vinet;S. Vilalte;S. Vitale;H. Vocca;R. L. Ward;M. Was;K. Yamamoto;M. Yvert;J. P. Zendri;Z. Zhang
2012-01-01
Abstract
This paper presents a complete description of Virgo, the French-Italian gravitational wave detector. The detector, built at Cascina, near Pisa (Italy), is a very large Michelson interferometer, with 3 km-long arms. In this paper, following a presentation of the physics requirements, leading to the specifications for the construction of the detector, a detailed description of all its different elements is given.These include civil engineering infrastructures, a huge ultra-high vacuum (UHV) chamber (about 6000 cubic metres), all of the optical components, including high quality mirrors and their seismic isolating suspensions, all of the electronics required to control the interferometer and for signal detection. The expected performances of these different elements are given, leading to an overall sensitivity curve as a function of the incoming gravitational wave frequency. This description represents the detector as built and used in the first data-taking runs. Improvements in different parts have been and continue to be performed, leading to better sensitivities. These will be detailed in a forthcoming paper.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/3120036
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
290
255
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.