Here we report a case of a 79-year-old woman with inferior myocardial infarction, transferred to our cath lab to perform a primary percutaneous coronary intervention (PPCI). During the procedure, a massive dissection complicated the thrombotic lesion of the right coronary artery (RCA). In this case, we decided to use the MGuard stent to treat both the large dissection and the thrombotic lesion. MGuard stent is a combination of a coronary stent merged with an embolic protection device. After multiple MGuard stent implantation we obtained a complete resolution of the coronary dissection obtaining a patent RCA with normal antegrade flow
Multiple MGuard stent implantation to treat massive right coronary artery dissection during primary coronary angioplasty.
PISCIONE, Federico;
2011-01-01
Abstract
Here we report a case of a 79-year-old woman with inferior myocardial infarction, transferred to our cath lab to perform a primary percutaneous coronary intervention (PPCI). During the procedure, a massive dissection complicated the thrombotic lesion of the right coronary artery (RCA). In this case, we decided to use the MGuard stent to treat both the large dissection and the thrombotic lesion. MGuard stent is a combination of a coronary stent merged with an embolic protection device. After multiple MGuard stent implantation we obtained a complete resolution of the coronary dissection obtaining a patent RCA with normal antegrade flowFile in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.