Although mammography remains the technique of choice for the early detection of breast cancer, several imaging techniques, including scintimammography and magnetic resonance imaging (MRI), have recently been proposed as adjuncts for this purpose and included in many diagnostic protocols. This study was undertaken to assess the clinical accuracy of scintimammography with technetium-99m methoxyisobutylisonitrile (MIBI) and contrast-enhanced MRI in the detection of primary breast carcinoma in patients with equivocal mammographic findings. Forty-nine patients with a suspicious breast mass detected either by physical examination or by mammography and ultrasound (US) were studied. All patients underwent scintimammography and dynamic contrast-enhanced MRI 1 week apart. The results of the two techniques were compared and correlated to the final diagnoses. Two independent readers reported the scans using a four-point confidence scale. The areas under the receiver operator characteristic (ROC) curves were obtained. Scintimammography showed an accuracy for tumour detection of 84\%, with a sensitivity of 80\% and a specificity of 88\%. MRI showed an accuracy of 86\%, with a sensitivity and specificity of 96\% and 75\%, respectively. Comparison of the two areas under the ROC curves showed no significant differences between MRI, 0.91+/-0.05 (mean+/-SD), and scintimammography, 0.88+/-0.05 (P=0.9). It is concluded that dynamic MRI and scintimammography possess comparable accuracy in the diagnosis of primary breast carcinoma in patients with equivocal mammographic or US findings.

Scintimammography with 99mTc-MIBI versus dynamic MRI for non-invasive characterization of breast masses.

PACE, Leonardo;DI SALLE, Francesco;
2001-01-01

Abstract

Although mammography remains the technique of choice for the early detection of breast cancer, several imaging techniques, including scintimammography and magnetic resonance imaging (MRI), have recently been proposed as adjuncts for this purpose and included in many diagnostic protocols. This study was undertaken to assess the clinical accuracy of scintimammography with technetium-99m methoxyisobutylisonitrile (MIBI) and contrast-enhanced MRI in the detection of primary breast carcinoma in patients with equivocal mammographic findings. Forty-nine patients with a suspicious breast mass detected either by physical examination or by mammography and ultrasound (US) were studied. All patients underwent scintimammography and dynamic contrast-enhanced MRI 1 week apart. The results of the two techniques were compared and correlated to the final diagnoses. Two independent readers reported the scans using a four-point confidence scale. The areas under the receiver operator characteristic (ROC) curves were obtained. Scintimammography showed an accuracy for tumour detection of 84\%, with a sensitivity of 80\% and a specificity of 88\%. MRI showed an accuracy of 86\%, with a sensitivity and specificity of 96\% and 75\%, respectively. Comparison of the two areas under the ROC curves showed no significant differences between MRI, 0.91+/-0.05 (mean+/-SD), and scintimammography, 0.88+/-0.05 (P=0.9). It is concluded that dynamic MRI and scintimammography possess comparable accuracy in the diagnosis of primary breast carcinoma in patients with equivocal mammographic or US findings.
2001
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/3765324
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 15
social impact