BACKGROUND: displaced transverse fractures of the olecranon are the most common fractures occurring in the elbow in adults that requires operative intervention. METHODS: a literature search was performed on PubMed, Web of Science, Science Direct/Scopus, Google Scholar and Google using the keywords 'olecranon', 'fracture', 'internal fixation' and 'tension band wiring', with no limit for time or restrictions to language. RESULTS: thirty-one clinical articles were selected: 20 retrospective studies, 9 prospective cohort studies, and 2 randomized control trials. The CMS ranged from 18 to 66 (mean 41.68): overall, the quality of the studies was poor, and no moderate or good quality studies were found. The mean follow-up was 46.7 months (range 1 to 350 months). Several complications occurred after surgery: prominent hardware, skin breakdown, wire migration and infections occurred frequently. Removal of the hardware was required in 472 patients, usually after complaints, but also removal was routinely undertaken. CONCLUSIONS: tension band wiring is still the most widely applied method to operatively manage olecranon fractures, with the transcortical method of using K-wires the most satisfactory. Plate fixation is a good alternative as complications are minimal. Other techniques using absorbable sutures are less investigated, but are promising, especially in children.

Current techniques for management of transverse displaced olecranon fractures.

Oliva, Francesco;MAFFULLI, Nicola
2015-01-01

Abstract

BACKGROUND: displaced transverse fractures of the olecranon are the most common fractures occurring in the elbow in adults that requires operative intervention. METHODS: a literature search was performed on PubMed, Web of Science, Science Direct/Scopus, Google Scholar and Google using the keywords 'olecranon', 'fracture', 'internal fixation' and 'tension band wiring', with no limit for time or restrictions to language. RESULTS: thirty-one clinical articles were selected: 20 retrospective studies, 9 prospective cohort studies, and 2 randomized control trials. The CMS ranged from 18 to 66 (mean 41.68): overall, the quality of the studies was poor, and no moderate or good quality studies were found. The mean follow-up was 46.7 months (range 1 to 350 months). Several complications occurred after surgery: prominent hardware, skin breakdown, wire migration and infections occurred frequently. Removal of the hardware was required in 472 patients, usually after complaints, but also removal was routinely undertaken. CONCLUSIONS: tension band wiring is still the most widely applied method to operatively manage olecranon fractures, with the transcortical method of using K-wires the most satisfactory. Plate fixation is a good alternative as complications are minimal. Other techniques using absorbable sutures are less investigated, but are promising, especially in children.
2015
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4650488
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact