In this study, the viability of using electrocoagulation process as a method for pharmaceuticals removal from real municipal wastewater was demonstrated. Batch experimental runs were performed using a simple laboratory scale electrochemical reactor with aluminium and stainless steel as anode and cathode, respectively. Diclofenac (DCF), carbamazepine (CBZ) and amoxicillin (AMX) were selected as representative of pharmaceuticals frequently detected in the aquatic environment. The effects of varying experimental parameters namely current density (0.3, 0.5 1.15 and 1.8 mA cm−2), initial pharmaceutical concentration (0.01, 4 and 10 mg L-1), electrolysis duration (3, 6 and 19 h) and application mode (continuous vs. intermittent) on pharmaceutical removal efficiencies were evaluated. High pharmaceutical abatement was recorded at elevated current density and prolonged electrolysis duration due to additional electro-generated coagulant species in solution.

Applicability of the electrocoagulation process in treating real municipal wastewater containing pharmaceutical active compounds

Borea, Laura;Naddeo, Vincenzo
;
Belgiorno, Vincenzo;
2018-01-01

Abstract

In this study, the viability of using electrocoagulation process as a method for pharmaceuticals removal from real municipal wastewater was demonstrated. Batch experimental runs were performed using a simple laboratory scale electrochemical reactor with aluminium and stainless steel as anode and cathode, respectively. Diclofenac (DCF), carbamazepine (CBZ) and amoxicillin (AMX) were selected as representative of pharmaceuticals frequently detected in the aquatic environment. The effects of varying experimental parameters namely current density (0.3, 0.5 1.15 and 1.8 mA cm−2), initial pharmaceutical concentration (0.01, 4 and 10 mg L-1), electrolysis duration (3, 6 and 19 h) and application mode (continuous vs. intermittent) on pharmaceutical removal efficiencies were evaluated. High pharmaceutical abatement was recorded at elevated current density and prolonged electrolysis duration due to additional electro-generated coagulant species in solution.
2018
File in questo prodotto:
File Dimensione Formato  
4718024.pdf

accesso aperto

Descrizione: Pre-Print
Tipologia: Documento in Pre-print (manoscritto inviato all'editore, precedente alla peer review)
Licenza: Creative commons
Dimensione 2.23 MB
Formato Adobe PDF
2.23 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4718024
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 80
  • ???jsp.display-item.citation.isi??? 72
social impact