Externally Bonded Reinforcement on Groove (EBROG) method has been introduced to enhance the bond resistance of FRP strips to concrete. It has demonstrated that EBROG generally outperforms EBR in terms of loadtransfer capacity between FRP strips and concrete. The present study aims to further demonstrate the potential of EBROG applied for flexural strengthening. A specimen reinforced according to the EBR solution and a nominally equal one reinforced through the EBROG system are first presented. Then, the performance of a newly fully-composite mechanical end anchorage for prestressed FRP strip to be used in conjunction with the EBROG method is investigated. The experimental results show that the premature debonding observed in EBR is avoided by EBROG in the case of "passive" FRP strips. Moreover, the combination of EBROG and end anchorage demonstrates their effectiveness, as the pre-stressed slab exhibits the full exploitation of the FRP up to rupture. Numerical analyses, carried out by means of a model already presented by the authors, show that the structural response of the tested slabs can be simulated in a very accurate manner if consistent assumptions are made in terms of bond-slip laws adopted to describe the interaction between FRP and concrete in EBR and EBROG.

Experimental tests and numerical simulations on the mechanical response of RC slabs externally strengthened by passive and prestressed FRP strips

Martinelli, E;
2023-01-01

Abstract

Externally Bonded Reinforcement on Groove (EBROG) method has been introduced to enhance the bond resistance of FRP strips to concrete. It has demonstrated that EBROG generally outperforms EBR in terms of loadtransfer capacity between FRP strips and concrete. The present study aims to further demonstrate the potential of EBROG applied for flexural strengthening. A specimen reinforced according to the EBR solution and a nominally equal one reinforced through the EBROG system are first presented. Then, the performance of a newly fully-composite mechanical end anchorage for prestressed FRP strip to be used in conjunction with the EBROG method is investigated. The experimental results show that the premature debonding observed in EBR is avoided by EBROG in the case of "passive" FRP strips. Moreover, the combination of EBROG and end anchorage demonstrates their effectiveness, as the pre-stressed slab exhibits the full exploitation of the FRP up to rupture. Numerical analyses, carried out by means of a model already presented by the authors, show that the structural response of the tested slabs can be simulated in a very accurate manner if consistent assumptions are made in terms of bond-slip laws adopted to describe the interaction between FRP and concrete in EBR and EBROG.
File in questo prodotto:
File Dimensione Formato  
ES_2023_compressed.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.48 MB
Formato Adobe PDF
2.48 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4838391
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact