Purpose: To assess the impact of prostate MRI image quality by means of the Prostate Imaging Quality (PI-QUAL) score, on the identification of extraprostatic extension of disease (EPE), predicted using the EPE Grade Score, Likert Scale Score (LSS) and a clinical nomogram (MSKCCn). Methods: We retrospectively included 105 patients with multiparametric prostate MRI prior to prostatectomy. Two radiologists evaluated image quality using PI-QUAL (>4 was considered high quality) in consensus. All cases were also scored using the EPE Grade, the LSS, and the MSKCCn (dichotomized). Inter-rater reproducibility for each score was also assessed. Accuracy was calculated for the entire population and by image quality, considering two thresholds for EPE Grade (>2 and = 3) and LSS (>3 and > 4) and using McNemar's test for comparison. Results: Overall, 66 scans achieved high quality. The accuracy of EPE Grade ranged from 0.695 to 0.743, while LSS achieved values between 0.705 and 0.733. Overall sensitivity for the radiological scores (range = 0.235-0.529) was low irrespective of the PI-QUAL score, while specificity was higher (0.775-0.986). The MSKCCn achieved an AUC of 0.76, outperforming EPE Grade (=3 threshold) in studies with suboptimal image quality (0.821 vs 0.564, p = 0.016). EPE Grade (=3 threshold) accuracy was also better in high image quality studies (0.849 vs 0.564, p = 0.001). Reproducibility was good to excellent overall (95 % Confidence Interval range = 0.782-0.924). Conclusion: Assessing image quality by means of PI-QUAL is helpful in the evaluation of EPE, as a scan of low quality makes its performance drop compared to clinical staging tools.

MR image quality in local staging of prostate cancer: Role of PI-QUAL in the detection of extraprostatic extension

Cuocolo, Renato
2023-01-01

Abstract

Purpose: To assess the impact of prostate MRI image quality by means of the Prostate Imaging Quality (PI-QUAL) score, on the identification of extraprostatic extension of disease (EPE), predicted using the EPE Grade Score, Likert Scale Score (LSS) and a clinical nomogram (MSKCCn). Methods: We retrospectively included 105 patients with multiparametric prostate MRI prior to prostatectomy. Two radiologists evaluated image quality using PI-QUAL (>4 was considered high quality) in consensus. All cases were also scored using the EPE Grade, the LSS, and the MSKCCn (dichotomized). Inter-rater reproducibility for each score was also assessed. Accuracy was calculated for the entire population and by image quality, considering two thresholds for EPE Grade (>2 and = 3) and LSS (>3 and > 4) and using McNemar's test for comparison. Results: Overall, 66 scans achieved high quality. The accuracy of EPE Grade ranged from 0.695 to 0.743, while LSS achieved values between 0.705 and 0.733. Overall sensitivity for the radiological scores (range = 0.235-0.529) was low irrespective of the PI-QUAL score, while specificity was higher (0.775-0.986). The MSKCCn achieved an AUC of 0.76, outperforming EPE Grade (=3 threshold) in studies with suboptimal image quality (0.821 vs 0.564, p = 0.016). EPE Grade (=3 threshold) accuracy was also better in high image quality studies (0.849 vs 0.564, p = 0.001). Reproducibility was good to excellent overall (95 % Confidence Interval range = 0.782-0.924). Conclusion: Assessing image quality by means of PI-QUAL is helpful in the evaluation of EPE, as a scan of low quality makes its performance drop compared to clinical staging tools.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4840680
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact