OBJECTIVE Different surgical routes have been used over the years to achieve adequate decompression of the optic nerve in its canal including, more recently, endoscopic approaches performed either through the endonasal corridor or the transorbital one. The present study aimed to detail and quantify the amount of bone removal around the optic canal, achievable via medial-to-lateral endonasal and lateral-to-medial transorbital endoscopic trajectories. METHODS Five human cadaveric heads (10 sides) were dissected at the Laboratory of Surgical Neuroanatomy of the University of Barcelona (Spain). The laboratory rehearsals were run as follows: 1) preliminary preoperative CT scans of each specimen, 2) anatomical endoscopic endonasal and transorbital dissections and Dextroscope-based morphometric analysis, and 3) quantitative analysis of optic canal bone removal for both endonasal and transorbital endoscopic approaches. RESULTS The endoscopic endonasal route permitted exposure and removal of the most inferomedial portion of the optic canal (an average of 168), whereas the transorbital pathway allowed good control of its superolateral part (an average of 192). Considering the total circumference of the optic canal (360), the transorbital route enabled removal of a mean of 53.3% of bone, mainly the superolateral portion. The endonasal approach provided bone removal of a mean of 46.7% of the inferomedial aspect. This result was found to be statistically significant (p < 0.05). The morphometric analysis performed with the aid of the Dextroscope (a virtual reality environment) showed that the simulation of the transorbital trajectory may provide a shorter surgical corridor with a wider angle of approach (39.6 mm; 46.8) compared with the simulation of the endonasal pathway (52.9 mm; 23.8). CONCLUSIONS Used together, these 2 endoscopic surgical paths (endonasal and transorbital) may allow a 360 decompression of the optic nerve. To the best of the authors' knowledge, this is the first anatomical study on transorbital optic nerve decompression to show its feasibility. Further studies and, eventually, surgical case series are mandatory to confirm the effectiveness of these approaches, thereby refining the proper indications for each of them.

Endoscopic endonasal medial-to-lateral and transorbital lateral-to-medial optic nerve decompression: an anatomical study with surgical implications

de Notaris M;
2017-01-01

Abstract

OBJECTIVE Different surgical routes have been used over the years to achieve adequate decompression of the optic nerve in its canal including, more recently, endoscopic approaches performed either through the endonasal corridor or the transorbital one. The present study aimed to detail and quantify the amount of bone removal around the optic canal, achievable via medial-to-lateral endonasal and lateral-to-medial transorbital endoscopic trajectories. METHODS Five human cadaveric heads (10 sides) were dissected at the Laboratory of Surgical Neuroanatomy of the University of Barcelona (Spain). The laboratory rehearsals were run as follows: 1) preliminary preoperative CT scans of each specimen, 2) anatomical endoscopic endonasal and transorbital dissections and Dextroscope-based morphometric analysis, and 3) quantitative analysis of optic canal bone removal for both endonasal and transorbital endoscopic approaches. RESULTS The endoscopic endonasal route permitted exposure and removal of the most inferomedial portion of the optic canal (an average of 168), whereas the transorbital pathway allowed good control of its superolateral part (an average of 192). Considering the total circumference of the optic canal (360), the transorbital route enabled removal of a mean of 53.3% of bone, mainly the superolateral portion. The endonasal approach provided bone removal of a mean of 46.7% of the inferomedial aspect. This result was found to be statistically significant (p < 0.05). The morphometric analysis performed with the aid of the Dextroscope (a virtual reality environment) showed that the simulation of the transorbital trajectory may provide a shorter surgical corridor with a wider angle of approach (39.6 mm; 46.8) compared with the simulation of the endonasal pathway (52.9 mm; 23.8). CONCLUSIONS Used together, these 2 endoscopic surgical paths (endonasal and transorbital) may allow a 360 decompression of the optic nerve. To the best of the authors' knowledge, this is the first anatomical study on transorbital optic nerve decompression to show its feasibility. Further studies and, eventually, surgical case series are mandatory to confirm the effectiveness of these approaches, thereby refining the proper indications for each of them.
2017
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11386/4858492
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 43
social impact